A practical method to test the safety of HV/MV substation Grounding Systems

2015

The adequacy of a Grounding System (GS) to the safety conditions has to be periodically tested by measurements. The test methods and techniques used to verify the electrical characteristics of the GS include the measurements of step and touch voltages. The goal of the test is to verify that touch voltage and step voltage remain below a safe value in all the zones of the installation. The measurements can present some operational difficulties. The purpose of this paper is to present the procedure, step-by-step, of a practical method of measuring touch/step voltages in grounding systems located in urban or industrial areas with reduced accessibility. The suggested method uses auxiliary curren…

Engineeringbusiness.industryGroundEnergy Engineering and Power Technologyglobal grounding systemground potentialgrounding systemEarthing systemelectrical safety; global grounding system; ground potential; grounding system; electrical and electronic engineering; energy engineering and power technologyElectrical safety; grounding system; Global Grounding System; Ground potentialTest (assessment)Settore ING-IND/33 - Sistemi Elettrici Per L'EnergiaSettore ING-IND/31 - ElettrotecnicaElectronic engineeringElectrical and Electronic EngineeringbusinessSimulationVoltageElectrical safety
researchProduct

Influence of LV neutral grounding on global earthing systems

2015

International Standards define a Global Earthing System as an earthing net created interconnecting local Earthing Systems (generally through the shield of MV cables and/or bare buried conductors). In Italy, the regulatory authority for electricity and gas requires distributors to guarantee the electrical continuity of LV neutral conductor. This requirement has led to the standard practice of realizing “reinforcement groundings” along the LV neutral conductor path and at users’ delivery cabinet. Moreover, in urban high-load scenarios (prime candidates to be part of a Global Earthing System), it is common that LV distribution scheme creates, through neutral conductors, an effective connection…

Engineeringelectrical and electronic engineeringmaxwell subareas method020209 energyEnergy Engineering and Power TechnologyGround and neutralindustrial and manufacturing engineering02 engineering and technologyRegulatory authorityGlobal earthing system (GES) global grounding system (GGS) ground potential LV neutral conductor maxwell subareas method.control and systems engineeringlv neutral conductorShield0202 electrical engineering electronic engineering information engineeringglobal earthing systemmaxwell sub-areas methodGlobal earthing system (GES)Electrical conductorglobal grounding system (GGS)Groundbusiness.industryGES; GGS; global earthing system; global grounding system; ground potential; lv neutral conductor; maxwell sub-areas method; control and systems engineering; industrial and manufacturing engineering; electrical and electronic engineeringElectrical engineeringGlobal Earting SystemGESglobal grounding systemground potentialEarthing systemGGSGlobal earthing system (GES); global grounding system (GGS); ground potential; LV neutral conductor; maxwell subareas method; Control and Systems Engineering; Industrial and Manufacturing Engineering; Electrical and Electronic EngineeringSettore ING-IND/33 - Sistemi Elettrici Per L'EnergiaSettore ING-IND/31 - ElettrotecnicaGlobal Earting System; GES; Global Grounding System; GGS; Ground potential; Maxwell Sub-areas Method; LV neutral conductorHigh loadElectricityGES; GGS; Global earting system; global grounding system; ground potential; lv neutral conductor; maxwell sub-areas method; electrical and electronic engineering; energy engineering and power technologybusiness
researchProduct

Ground potential rise at transition poles of combined overhead-cable lines due to the fault application transfer phenomenon

2008

combined head-cable lines: ground potential rise
researchProduct